|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
OxyProof K Series Pressure transmitters for oxygen applications ENGINEERING PROPOSAL FEATURES * BAM safety approval for oxygen applications11 * 0...-1 to 0...350 bar, gage or absolute * 0...10 V, 0.5...4.5 V, 0...5 V and 4...20 mA output * Field interchangeable MEDIA COMPATIBILITY Pressure inlet: all media compatible with stainless steel 1.4404 (316L), ceramic Al2O3 and FKM Housing: stainless steel, protection class IP65 according to DIN400501 SPECIFICATIONS9,10 Maximum ratings ELECTRICAL CONNECTION 0...10 V, 0.5...4.5 V, 0...5 V output Supply voltage (reverse polarity protection) for 0...10 V output 12...30 V for 0.5...4.5 V and 0...5 V output 9...30 V for 4...20 mA output2 9...30 V Maximum load current (source) for all voltage outputs Temperature limits Storage Operating Compensated Humidity limits Vibration (5 to 500 Hz) Mechanical shock Proof pressure3 +Vs 1 Vout 3 -Vs 2 12 (9) to 30 V sensor V 1 mA GND -20 to 100 C -10 to 60 C 0 to 60 C 0 - 95 %RH 10 gRMS 50 g 2 x rated pressure 4...20 mA output +Vs 1 N/C 3 -Vs 2 9 to 30 V sensor V RL GND March 2008 / 640 1/5 www.sensortechnics.com OxyProof K Series Pressure transmitters for oxygen applications ENGINEERING PROPOSAL COMMON PERFORMANCE CHARACTERISTICS VS = 15 V, RL > 100 k, tamb = 25C Characteristics Operating pressures Min. 0 -1 -1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Typ. Max. 1 1 0 2 5 10 16 20 25 35 50 70 100 150 200 250 350 0.05 0.05 Unit bar Thermal effects (0 to 60 C)4 Thermal effects (-40 to 0 C) Non-linearity, hysteresis (BSL) and repeatability5 Long term stability6 Output noise (0 < f < 1 kHz) Response time (10 to 90 %) Power supply rejection Offset Span Offset Span > 200 bar all others 0.02 0.02 0.03 0.03 0.20 0.15 0.3 0.04 10 %FSO/C 0.40 0.25 %FSO ms Offset Span voltage output current output voltage output current output 0.002 0.05 0.002 0.08 %FSO/V March 2008 / 640 2/5 www.sensortechnics.com OxyProof K Series Pressure transmitters for oxygen applications ENGINEERING PROPOSAL INDIVIDUAL PERFORMANCE CHARACTERISTICS 0...10 V output (VS = 15 V, RL > 100 k, tamb = 25C) Characteristics Zero pressure offset Full scale span7 Output impedance Current consumption (no load) 0...1 bar devices all others 0...1 bar devices all others Min. 4.9 4.9 9.9 Typ. 5 0.03 5 10 Max. 5.1 0.1 5.1 10.1 25 Unit V mA 3 5 0.5...4.5 V output (VS = 15 V, RL > 100 k, tamb = 25C) Characteristics Zero pressure offset Full scale span7 Output impedance Current consumption (no load) 0...1 bar devices all others 0...1 bar devices all others Min. 2.450 0.450 1.950 3.950 Typ. 2.5 0.5 2 4 Max. 2.550 0.550 2.050 4.050 25 Unit V mA 3 5 0...5 V output (VS = 15 V, RL > 100 k, tamb = 25C) Characteristics Zero pressure offset Full scale span7 Output impedance Current consumption (no load) 4...20 mA output (VS = 15 V, RL = 100 , tamb = 25C) Min. 2.45 2.45 4.95 Typ. 2.5 0.03 2.5 5.0 Max. 2.55 0.08 2.55 5.05 25 Unit V mA 0...1 bar devices all others 0...1 bar devices all others 3 5 Characteristics Zero pressure offset Full scale span7 Power consumption (IL = 20 mA) 0...1 bar devices all others 0...1 bar devices all others Min. 11.9 3.9 7.9 15.9 Typ. 12.0 4.0 8.0 16.0 250 Max. 12.1 4.1 8.1 16.1 Unit mA mW March 2008 / 640 3/5 www.sensortechnics.com OxyProof K Series Pressure transmitters for oxygen applications ENGINEERING PROPOSAL ELECTROMAGNETIC CAPABILITY8 Test conditions Radiated, radio frequency electromagnetic field immunity (RFI) EN61000-4-3: Grade 3, 10 V/m, 80 to 1000 MHz 80 % AMC (1 kHz) Criterion A B B A Interference <1 %FSO <1 %FSO <1 %FSO <1 %FSO Electrical fast transient / burst immunity (EFT) EN61000-4-4: Grade 3, 2 kV Electrostatic discharge immunity test (ESD) Immunity to conducted disturbances induced by radio-frequency fields EN61000-4-2: Grade 4, 8 kV, contact discharge EN61000-4-6: Grade 3, 0.15 to 80 MHz 10 V, 80 % AMC (1 kHz) LOAD LIMITATION 4...20 mA output version 1400 Ohm 1200 1000 800 op e ra ratin ng g e RECOMMENDED PLUG (DIN 43650-A) Plug and profile washer included in delivery! 600 400 200 0 5 9 16 20 25 30 V supply voltage dimensions in mm Specification notes (for all devices): The package is an all-sealed housing. IP65 protection is given when the connector is locked with a rubber washer. For proper function the gage port is vented to the atmosphere through the connector/cable assembly. Thus the cable end must have access to the ambient pressure. 2. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the load limitation diagram. 3. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. 4. Thermal effects tested and guaranteed from 0 to 60C relative to 25C. All specifications shown are relative to 25C. 5. Non-linearity refers to the Best Straight Line fit measured for offset, full scale span and 1/2 full scale span. 6. Long term stability is the change in output after one year or 1 million pressure cycles. 7. Span is the arithmetic difference in transmitter output signal measured at zero pressure and the maximum operating pressure. 8. Test are in accordance with EN61000-6-2, April 1999. 9. CE-labelling is in accordance with 89/336/EEC. 10. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC. 11. BAM certification-No: BAM/ZBA/001/07. The BAM certificate refers only to the burn-out safety of the materials in oxygen service. 1. March 2008 / 640 4/5 www.sensortechnics.com OxyProof K Series Pressure transmitters for oxygen applications ENGINEERING PROPOSAL OUTLINE DRAWING Electrical termination: DIN 43650-A Pressure connection: G 1/4" (1/4" BSP) 4.5 (0.18) HEX 27 (1.06) 12 (0.47) NOM 68 (2.86) 8.5 (0.33) 12 (0.47) vent hole 3 G1/4" (1/4" BSP) 27.0 (1.06) diam. 2 1 mass: 210 g dimensions in mm (inches) Note: Other pressure ranges, output signals, electrical terminations and pressure connections are available on request. Minimum order quantity may apply. Please contact your nearest Sensortechnics sales office for further information. Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. March 2008 / 640 5/5 www.sensortechnics.com |
Price & Availability of OXYPROOF-K |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |